Submarine Cables Explained: Types, Repeaters, Power Feeding & Cable Landing Stations

Posted on November 17, 2026 by Engr. Hamid Ali

A comprehensive engineering guide to submarine fiber-optic networks, repeaters, constant-current HVDC power feeding, cable landing stations, shore crossings, subsea installation and submarine power transmission.

How does a signal cross an ocean? Why do underwater optical amplifiers need electricity, and how is it supplied from shore? What does a Cable Landing Station contain? This guide explains the full system for electrical, telecom, civil and EPC engineers.

What Are Submarine Cables?

Submarine cables are engineered cables installed on or beneath the seabed to transmit digital information or electrical power. Two fundamentally different systems exist: submarine telecommunications cables, which carry optical signals in glass fibers, and submarine power cables, which transmit electricity using HVAC or HVDC technology. Their installation environments overlap, but their operating principles, equipment and engineering requirements differ.

Why We Use Submarine Cables

Submarine telecommunications cables connect countries, cloud platforms, data centers, financial networks and internet service providers. They provide enormous aggregate bandwidth and generally predictable latency compared with satellite-only connectivity. Submarine power cables interconnect national grids, supply islands and offshore installations, and export offshore wind power. Physical submarine connections are used where terrestrial routes are impossible, inefficient or strategically less suitable.

Where Submarine Cables Are Used

Major telecommunications routes cross the Atlantic, Pacific and Indian Oceans, and regional seas including the Mediterranean, Red Sea and Arabian Gulf. Saudi Arabia’s coastal geography makes submarine landing and terrestrial backhaul infrastructure important for international connectivity. Explore existing and planned routes on the TeleGeography submarine cable map.

Types and Construction of Submarine Telecom Cables

Unrepeatered systems operate without submerged optical amplifiers and are suited to shorter routes. Repeatered systems include submerged amplifiers for long-haul links. Cable armor is selected separately: lightweight cables are common in protected deep water, while single- or double-armored designs may be required near shores or other high-risk areas.

A repeatered cable typically contains optical fibers, fiber protection, metallic DC power-feeding conductor, steel strength members, electrical insulation and—where required—additional steel armor. The optical and electrical paths serve different purposes.

How Optical Data Travels Underwater

Transmitting equipment modulates light and injects it into optical fibers. Dense Wavelength Division Multiplexing (DWDM) allows multiple optical wavelengths to share a fiber. Coherent transmission, digital signal processing and Forward Error Correction improve capacity and reach. Space Division Multiplexing (SDM) increases total capacity through additional fiber pairs and optimized repeater power. As an illustrative capacity calculation, 16 fiber pairs carrying 12 Tbps per pair would provide 192 Tbps of nominal system capacity; actual achievable performance depends on the design.

Why Underwater Repeaters and Amplifiers Are Necessary

Optical fibers attenuate signals over distance. At an illustrative attenuation of 0.16 dB/km, a 6,000 km route would have 960 dB of fiber attenuation before considering other losses. Submerged optical amplifiers therefore compensate for span loss. Many long-haul systems use Erbium-Doped Fiber Amplifiers (EDFAs), which use pump lasers to amplify light directly rather than electrically regenerating every bit. Spacing might be around 50–100 km in some designs, but is engineered from the optical power budget. Amplification also adds noise, so optical signal-to-noise ratio, nonlinear effects and equalization are critical.

How Underwater Repeaters Receive Electricity

This is the essential distinction between a submarine cable and an ordinary fiber link. A Power Feeding Equipment (PFE) system at the Cable Landing Station supplies regulated high-voltage DC current through a metallic conductor inside the submarine cable. The submerged repeaters’ power modules are connected in series along the power-feeding circuit. Seawater/earth electrodes provide the electrical return path in applicable feeding arrangements; optical signals never travel through seawater.

Because the repeaters are series-fed, the same current flows through the relevant repeater power modules. The terminal voltage must overcome conductor resistance, repeater voltage drops and other system allowances.

LANDING A                         UNDERSEA CABLE                         LANDING B
PFE (+) ─────── [Repeater 1] ─── [Repeater 2] ─── [Repeater N] ─────── PFE (−)
   │                                                                         │
Sea-earth electrode  · · · · · seawater / earth return · · · · ·  Sea-earth electrode

Optical fibers: independent bidirectional optical transmission path
Metallic conductor: high-voltage DC power feeding path
Conceptual diagram only. Actual polarity, sea-earth configuration, branching and power-feed switching depend on the supplier design.

Worked Example: PFE Voltage and Power

Assume a 6,000 km cable with conductor resistance of 1 Ω/km, constant current of 1 A, and 80 repeaters each dropping 50 V. Cable voltage drop = 1 × 6,000 = 6,000 V. Repeater voltage drop = 80 × 50 = 4,000 V. Total illustrative terminal voltage = 10,000 V DC; total input power = 10,000 × 1 = 10 kW. This 10 kW includes conductor losses and repeater consumption; it is not the rating of each repeater.

Actual design must account for branching units, electrode potentials, insulation, fault modes, voltage margin and maintenance arrangements. The figures are illustrative, not procurement specifications.

Single-End and Double-End Power Feeding

With single-end feeding, one shore terminal provides the required voltage/current for the relevant cable section, using the engineered return path. With double-end feeding, both landing stations coordinate the required current and voltage. A conceptual 10 kV circuit could have approximately +5 kV at one terminal and −5 kV at the other relative to local earth. Some systems can switch to single-end feeding after a station failure, but this depends on PFE ratings, cable condition, branching configuration and protection design.

Cable Landing Station (CLS): Equipment and Functions

The CLS is the terrestrial interface between the underwater wet plant and the terrestrial dry plant/network. A typical station may contain:

  • CTB — Cable Termination Box: termination/interface for optical and electrical cable elements.
  • PFE — Power Feeding Equipment: regulated high-voltage DC supply for submerged repeaters.
  • SLTE — Submarine Line Terminal Equipment: coherent optical transmission and reception.
  • ODF — Optical Distribution Frame: fiber patching and management.
  • DWDM/optical line equipment: wavelength multiplexing and optical transport.
  • NMS: alarms, supervision and performance monitoring.
  • UPS, DC power, generators, HVAC, fire protection and security: station availability infrastructure.
  • Sea-earth electrode system: engineered PFE return/reference arrangement.

Depending on the architecture, SLTE may be at the coastal CLS or inland in a data center/point of presence.

How the CLS Connects to the Data Center

SUBMARINE WET PLANT
      │
Beach Manhole / Shore Crossing
      │
Land Cable Route
      │
Cable Landing Station ── PFE / CTB / Optical Interface
      │
Terrestrial Fiber Backhaul
      │
Data Center / Meet-Me Room
      │
Routers / Cloud / Internet Networks
Functional relationship. Optical terminals can be coastal or inland depending on the network design.

Co-location of a CLS and data center can shorten interconnection paths, but requires clear ownership boundaries, diverse fiber routes, independent availability assessments, security zoning and defined electrical and cooling redundancy.

CLS Electrical Power System

A CLS needs normal and backup building power as well as specialized PFE supply. A conceptual arrangement is:

Utility / MV-LV Supply ── LV Switchboard / ATS ──┬── UPS + Batteries ── Critical AC
                        ↑                         ├── Rectifiers / DC ── Telecom Loads
                  Standby Generator               ├── PFE ── Submarine Power Conductor
                                                  └── HVAC / Building Services
Functional block diagram only; final redundancy and segregation are project-specific.

Design considerations include utility redundancy, generator autonomy, UPS runtime, nominal −48 V telecom power where required, PFE protection, earthing and bonding, lightning/surge protection, precision cooling, fire suppression, BMS and remote alarms.

Beach Manhole, Shore Crossing and Branching Units

The Beach Manhole (BMH) is the near-shore underground chamber used for cable transition, jointing and maintenance access. Horizontal Directional Drilling (HDD) may protect the shore crossing beneath beaches or environmentally sensitive areas. Branching Units (BUs) connect trunk and branch cables for multiple landing countries; selected designs also provide electrical power-path switching so unaffected sections may remain operational after a fault.

Submarine Cable Route Survey and Installation

  1. Desktop route study: bathymetry, maritime boundaries, shipping, fishing, protected areas and existing utilities.
  2. Marine surveys: multibeam echo sounding, side-scan sonar, sub-bottom profiling and geotechnical sampling.
  3. Route engineering: depth, seabed risks, allowable tension, bend radius, burial and repair access.
  4. Shore-end construction: beach landing, BMH, ducts and optional HDD.
  5. Cable laying: specialized vessel controls tension, vessel speed, slack and deployment geometry.
  6. Protection: burial with plough or ROV where risk assessment requires it; deep-ocean sections may remain surface-laid.
  7. Testing: optical continuity/performance, electrical feeding, repeater monitoring, terminal and end-to-end acceptance.

Cable Faults, Repair and Network Resilience

Anchors, fishing activity, seabed movement and installation damage can cause cable faults. Operators use optical/electrical measurements to estimate fault location, mobilize a repair vessel, recover the affected section, cut out damaged cable, splice in a replacement, test and redeploy it. Repairs may take days or weeks after mobilization; permitting, weather, depth and vessel availability can extend restoration. Diverse routes and network rerouting can maintain some traffic, but capacity may still be constrained.

Submarine Power Cables: HVAC Versus HVDC

Submarine HVAC cables transmit alternating current and are widely used for shorter interconnectors and offshore wind export. Long AC cable capacitance creates charging current and reactive power demand. Approximate three-phase capacitive reactive power is Qc = 3 × 2πf × Cphase × Vphase².

HVDC submarine cables are often preferred for long-distance bulk transfer because they avoid steady-state AC cable charging current and can connect asynchronous grids. They require converter stations at their terminals. The economic crossover depends on power, distance, voltage, converter cost and losses—not a universal distance threshold.

Important: Submarine power cables do not contain regularly spaced optical-style booster stations. HVDC converter stations are different from telecom repeaters.

Emerging Submarine Cable Technologies

Key developments include SDM systems with more fiber pairs, open submarine cable architectures, advanced coherent modulation and DSP, improved optical monitoring, distributed fiber sensing and scientific cables with environmental or seismic sensors. Each technology has different maturity and deployment requirements.

EPC Tendering Scope and Interface Management

CLS EPC works may include civil/architectural facilities, BMH and duct banks, MV/LV distribution, UPS, batteries, generators, HVAC, fire protection, ODF/telecom rooms, security, earthing, PFE/SLTE interfaces, sea-earth systems and integrated testing.

Before pricing, clarify whether the contractor’s responsibility is limited to the CLS building and MEP works or includes the submarine wet plant, repeaters, branching units, marine installation and end-to-end optical performance. Confirm equipment supply boundaries, shore-end works, HDD, marine permits, interface control documents, testing responsibilities and warranty limits.

Engineering Documents and Standards

Important deliverables include design basis, cable landing layout, route drawings, SLDs, electrical load schedule, UPS/battery/generator sizing, PFE and sea-earth design, fiber/duct schedules, rack layouts, HVAC calculations, earthing and lightning studies, interface control documents, ITPs and commissioning procedures.

Useful references include ITU-T G.971, G.972, G.973/G.974 series, ITU-T G Supplement 41, relevant IEC power cable standards, CIGRE guidance and International Cable Protection Committee recommendations. Confirm the current edition and applicability for each project.

Frequently Asked Questions

Do repeaters have batteries? Conventional active repeaters receive DC power from shore-based PFE; they do not rely on local batteries for years of operation.

Can one CLS support multiple cables? Yes, subject to capacity, security, ownership and operational requirements.

Can a cable carry data and electricity? A repeatered telecom cable carries optical data and a separate DC feeding current within the same assembly, but not utility-scale power delivery.

How long do systems last? Many telecom systems target a nominal design life of about 25 years, with actual service life varying.

Are all repeaters 75 km apart? No. Repeater spacing depends on optical and electrical design.

Technical References and Further Reading

  • International Telecommunication Union — submarine optical cable recommendations
  • TeleGeography — Global Submarine Cable Map
  • International Cable Protection Committee
  • Ciena — optical submarine network resources
  • NEC — submarine systems and power feeding technology
  • CIGRE — power transmission technical publications

Technical note: All numerical examples are illustrative. Final design and equipment selection require project-specific calculations and manufacturer documentation.

Our Top Posts

  • List of Contractors who Won Major BSP Projects in 2024 in KSA
  • Top Electrical Engineering Courses on Coursera
  • List of Top Substation contractors in KSA
  • Transmission Line Design Important Points
  • Panels required inside substations
  • Electrical MCQs with Explanation of Answers
  • Electrical Past papers
  • How to Add MCQs in wordpress posts
  • Transmission Lines design Basics
  • 380kV Substation Design (22)
  • Al BABTAIN (2)
  • Al Gihaz (4)
  • AL-OJAIMI (2)
  • Alsharif Group (2)
  • Basic Electrical (7)
  • Basic Electronics (5)
  • BSP Projects (23)
  • Communication System (2)
  • Control System (2)
  • Control System MCQs (3)
  • Courses (11)
  • DATA Center (1)
  • electrical (8)
  • Electrical Courses (9)
  • Electrical Installations (3)
  • Electrical Jobs (8)
  • Electrical MCQs (13)
  • Electronics MCQs (9)
  • Energy Storage Systems (3)
  • Extra High Voltage EHV Substation Design (35)
  • Fellowships (3)
  • Fellowships in Pakistan (2)
  • Fellowships in Pakistan (1)
  • FPSC (1)
  • HV Substation Design (1)
  • HVDC Projects (1)
  • Information for Engineers (56)
  • Interview Preparation (46)
  • Jobs (11)
  • Jobs in KSA (11)
  • LV Switchgear (4)
  • MATLAB and Simulink (1)
  • MCQs (15)
  • Microsoft Excel (3)
  • Microwaves MCQs (1)
  • NTS Past Papers (4)
  • OHTL Projects (9)
  • Past Papers (10)
  • Power Transformer (5)
  • Research Work (6)
  • Safety MCQs (2)
  • Saudi ARAMCO (3)
  • Scholarships (4)
  • Scholarships in Pakistan (2)
  • Scholarships in Pakistan (2)
  • SEC Projects (30)
  • SSEM (3)
  • Synchronous Condensers (5)
  • TDP (2)
  • Transmission lines design (9)
  • Uncategorized (30)
  • Web Development (1)

Latest Posts

  • Submarine Cables Explained: Types, Repeaters, Power Feeding & Cable Landing Stations
  • Transformer Impedance: The Small Percentage That Changes an Entire Substation
  • Free Saudi Council of Engineers (SCE) Courses 2026: Registration & Certificates Guide
  • Current Transformer Protection Unit (CTPU): Operation, Selection, Wiring and Quantity Estimation
  • Can Grid-Forming Batteries Replace Synchronous Condensers? An Engineering Comparison Beyond MVAR

All Pages

  • Active Scholarships
  • C++ Data Structures
  • Electrical MCQs with explanation
  • Funny IQ Test – 20 Tricky Questions & Answers | Interactive Challenge
  • Funny IQ Test Part 2 – 20 New Tricky Questions & Answers
  • Jobs
  • Privacy Policy
  • Technical Posts
  • The World of Engineers
  • Top Electrical MCQs with explanation

Follow Us on

  • Facebook
  • YouTube
  • LinkedIn

© 2026 The World of Engineers | Powered by Superbs Personal Blog theme